Overview
This source page is a mechanical bulk-ingest record for a PDF in the research-pulls corpus. It preserves source-level identity, routeable product/analyte scope, and exact extracted numeric lines for later human or fresh-context audit. It does not derive HMTc thresholds, percentiles, or brand-by-brand comparisons.
Key numbers
The worker extracted the full PDF text with layout preservation twice and compared extraction hashes before commit. The following lines are copied from numeric/table-bearing regions of the PDF and retain the source units and wording where legible:
- • LOD, as low as 0.02 ppm for Hg (II), demonstrates the method’s sensitivity.
- figures of merit (R2 ≥ 0.940) and the low detection limits (0.05 ppm for As (III) ions and
- 0.02 ppm for Hg (II)) in serum albumin demonstrate the high sensitivity of the method.
- conditions of the Creative Commons ≥95% over a period of seven months without recalibrations, demonstrating the stability of
- selectivity for arsenic and mercury (28–31). The study also focused on using portable
- element ions (37). Blood levels of Hg below 50 µg/dL (or 0.5 ppm) are considered normal;
- Lyophilized human serum albumin (HSA) (agarose gel electrophoresis, purity > 97%),
- 3-(N-morpholino) propanesulfonic acid (MOPS, purity > 99.5%), L-cysteine, and gold
- used as received. As (III) and Hg (II) element reference standards (1000 ppm %) were
- and working range serum albumin solutions were prepared in MOPS buffer (30 mM,
- assays (42). The working range for As (III) or Hg (II) ion concentrations was prepared
- from 1000 ppm of As (III) or Hg (II) reference standard solutions. The absorption spectra
- device accessory, scanning the 200–600 nm wavelength range (bandwidth, 2.5 nm; quartz
- standard deviation from triplicate measurements (N = 3).
- of −33 mV, indicating that they are stable in water (Figure 2). Interestingly, the negative
- triplicate measurements (N = 3).
- HSA samples at varying known concentrations (0 ppm to 50 ppm) of either As(III) or
- as evidenced by LODs of 16 ppm and 29 ppm for As (III) and Hg (II), respectively. The
- element-specific (44). The LOD by XRF for arsenic detection in this study is comparable
- to the levels reported by Capobianco et al. for Pteris vittata (45). The use of a portable
- HSA 0µL Cys AuNP HSA 2ppm As 0µL Cys AuNP
- HSA + 4ppm As (III) HSA 6ppm As 0µL Cys AuNP
- HSA 8ppm As 0µL Cys AuNP HSA 10ppm As 0µL Cys AuNP
- HSA 12ppm As 0uL Cys AuNP
- HSA 2ppm Hg 0µL Cys AuNP HSA 4ppm Hg 0µL Cys AuNP
- HSA 6ppm Hg 0µL Cys AuNP HSA 8ppm Hg 0µL Cys AuNP
- HSA 10ppm Hg 0µL Cys AuNP HSA 12ppm Hg 0µL Cys AuNP
- Figure 3. (A) UV–visible spectra of a solution of varying concentrations (2 ppm to 12 ppm) of As (III)
- HSA was observed at higher Hg (II) concentrations (≥10 ppm), which could affect serum
- (II) ion concentrations (2 ppm to 12 ppm) in serum albumin with the addition of 25 µL of
- HSA 0µL Cys AuNP HSA 2ppm As 25µL Cys AuNP
- HSA 4ppm As 25µL Cys AuNP HSA 8ppm As 25µL Cys AuNP
- HSA 10ppm As 25µL Cys AuNP HSA 12ppm As 25µL Cys AuNP
- HSA 2ppm Hg 25µL Cys AuNP
- HSA 6ppm Hg 25µL Cys AuNP C
- HSA 4ppm Hg 25µL Cys AuNP
- HSA 8ppm Hg 25µL Cys AuNP
- solutions of varying As (III) ion concentrations (2 ppm to 12 ppm) in serum albumin with the addition
- of 25 µL of CysAuNPs (LOD = 0.02 ppm). (C) UV–visible absorption of solutions of varying Hg (II)
- ion concentrations (2 ppm to 12 ppm) in serum albumin with the addition of 25 µL of CysAuNPs
- analysis, and m is the slope of the regression line (64) of 0.05 ppm for As (III) and 0.02 ppm
- from these results is comparable to or lower than the reported LOD value of 0.026 ppm
Methods (brief)
- Human Serum Albumin Samples Using Cysteine-Capped
- • LOD, as low as 0.02 ppm for Hg (II), demonstrates the method’s sensitivity.
- relevant biological samples.
- (II) and As (III) in biological samples stems from the toxic effects of human exposure to
- distributed under the terms and (II) ions of independently prepared test validation samples in HSA with an accuracy of
- and determination of heavy metal ions in biological samples arises from the toxic and
- quantification of arsenic and mercury ions in serum samples, and CD spectroscopy for
- changes. Serum albumin and blood samples are vital in biomedical and toxicological
- 2.1. Chemicals, Consumables, and Sample Preparation
- pH 7.4), as previously described elsewhere (41). MOPS was selected for sample preparation
- were collected using a UV–visible spectrophotometer (Shimadzu 2600i) with a temperature-
- 2.2. Preparation of Nanoparticle Samples, Characterization, and Instrumental Analysis
- cuvette, 1 cm path length). The sample was equilibrated for one hour to allow for the
- at physiological conditions of 37 ◦ C and pH 7.4. The X-ray fluorescence (XRF) sample
- measurement was performed by filling XRF sample cups (30.7 mm OD × 22.9 mm high,
- 1330-SE, Chemplex Industries Inc., Palm City, FL, USA) with an HSA sample containing
- known concentrations of As (III) or Hg (II) ions. The sample was covered with a Prolene
- a Geochem (3-Beam) setting (50 kV three beam). Sample circular dichroism (CD) spectra
Implications
This page makes the source discoverable for category-level evidence routing. Values remain source-native and should be used only with the stated matrix, species, basis, geography, and censoring context from the paper. The page does not convert total mercury to methylmercury or use total arsenic as inorganic arsenic.
Wiki pages this source may touch
- Canned seafood (with tin flag)
- Fish — marine, predatory (tuna, swordfish, shark, king mackerel)
- Fish — marine, non-predatory (sardines, anchovies, salmon, cod)
- Mercury
- Mercury
- Cadmium
- Lead
- Arsenic
- Chromium
Verification notes
- Identity check: DOI, raw handle, candidate cite-key, and SHA-256 were compared against existing
wiki/sources/pages before creation. - Full-PDF read:
pdftotext -layoutwas run on the full PDF twice; extracted text hashes matched before the page was written. - Numeric verification: numeric/table-bearing lines were selected mechanically from the verified extraction and preserved without unit conversion or rounding.
- Brand firewall: the worker skips PDFs when extracted numeric lines appear brand/manufacturer-sensitive; this page contains category-level or species-level evidence only.
- HMTc firewall: no threshold, percentile, pass/fail, clean/dirty, or certification math is stated.
Update history
The five most recent substantive edits to this page, classified major (evidence or structure moved), correction (a published value or statement was wrong and has been fixed), or minor (narrative rewritten without changing the underlying evidence). Each description is derived from what the edit did to this page; the linked commit is the authoritative record, routine regeneration passes are excluded, and the full version history lives in git. When DOI minting comes online (see schema docs), each entry below will also link to a version-pinned DataCite DOI.