Rice finding 1120

Source evidence and comparison details for the Rice profile.

Román-Ochoa et al. 2021

Polished rice · Cadmium (Cd) · Sample count unreported.

Selected finding and reference

40 µg/kg (mean ± 20 SD)Mean.

Sample count unreported. Basis: unspecified.

no non-detects reported for this cell; source does not describe non-detect handling

HMI baseline position

Moderate · HMI uncooked-grain Cd reference · 13 sampling families. Mean as reported: 40 µg/kg. HMI median 22–28.5 (bounded); Q1 12; Q3 73 µg/kg. 13 families. Not a safety grade.

Low is below Q1; Moderate includes Q1 through Q3; High is above Q3. Reporting bounds must give the same category throughout.

This is an external comparison; the finding does not set the reference.

Sensitivity to weighting

Equal subgroup weight within each family: Moderate. The position is unchanged under this alternative. This check does not address all sampling, rounding or analytical uncertainty.

Sensitivity to source selection

These checks show dependence on each sampling family; they are not confidence intervals.

Reference, contributing evidence and methods

Collection period

2019

No year-by-year sample register is reconstructed from this summary.

Geographic scope

Polished rice, Region of Arequipa

Rice variety or type within one study.

Sampling, analysis and reporting limits

Grinding to flour, microwave-assisted HNO3 digestion (CEM MARS6), HR-ICP-MS (Thermo ELEMENT2) for Cd114, Sn118, Pb208 (medium resolution) and As75 (high resolution, total As); total Hg by CVAAS (EPA SW 846 7471B).

no non-detects reported for this cell; source does not describe non-detect handling

Shared samples and study overlap

Subgroup rows, statistics of the same subgroup and the study total share samples; they are not independent results.

Each table row describes a food/analyte result. Repeated rows do not add independent samples or datasets. No cross-study trend is calculated in this comparison mode.

Reported values, conversion and source locator
Source statisticOriginal resultDisplayed unit conversion
mean0.04 +/- 0.02 mg kg-1mg/kg x 1000

Original SD: 0.02 mg kg-1.

Section 3.4.1, p.10 ('Health risk assessment was only calculated for polished rice, and average concentrations for As, Cd, Sn, Pb, and Hg were 0.09 +/- 0.01, 0.04 +/- 0.02, 0.01 +/- 0.01, 0.01 +/- 0.01, and 0.0038 +/- 0.0002 mg kg-1').

No moisture, cooking-yield or species conversion is applied to the original finding above. Any basis conversion used for its HMI comparison is stated separately with the numerical target.

Open the primary publication · HMI source record

Reference and scope

HMI uncooked-grain Cd reference · 13 sampling families. Uncooked grain as analysed (native or unstated moisture), µg/kg. Distribution of subgroup median concentration values.

Reference (µg/kg)Q1MedianQ3
Primary HMI reference1222–28.5 (bounded)73
Alternative weighting1222–28.5 (bounded)73

129 reference units; 13 sampling families. Counts describe evidence units, not independent studies or certainty.

Contributing familyReference unitsWeight
Alrashdi et al. (2024)68%
WHO GEMS/Food428%
Mari et al. 201638%
Authors 201638%
Bazie et al. 202258%
Cantoral et al. 202418%
Ibrahim et al. 202418%
Li et al. 202438%
Limmer et al. 202618%
Liu et al. 202228%
Lockwood et al. 2023118%
Qin et al. 2026448%
Yan et al. (2025)78%

Methods

HMI calculates a pooled distribution of subgroup medians across the admitted sampling families. HMI pools subgroup medians from every compatible rice sampling family in the evidence ledger for this analyte, material and basis: published subgroup medians, medians HMI calculates from printed per-sample values and WHO GEMS/Food region-by-year medians (random sampling only). Each family has equal total weight; subgroups have equal weight within a family. Non-detects stay as zero-to-limit intervals, so quartiles carry lower and upper bounds. Means, ranges and maxima never enter as observations. Dry-weight, native-moisture and cooked results are kept in separate references; no moisture conversion is assumed.

Inverse weighted empirical CDF; midpoint at exact cumulative-weight boundaries. At least four reference units and a definitely positive Q1–Q3 spread are required. This is a display eligibility rule, not statistical validation.

Limitations

An evidence-library reference, not a probability sample of the world rice market. Sampling families differ in frame (retail, farm, contaminated sites, monitoring) and period; GEMS/Food regions are reporting regions, not growing origins. Many submissions are non-detects with differing limits, which widens the bounds. A position is descriptive concentration, not a safety or compliance judgment.

Admitted source families

Reference version and interpretation

Frozen evidence selection: 2026-10-22. Method: hmi-pooled-reference-v2.

hmi-pooled-reference-v2:rice-native-Cd:284df7d0ac5f

The reference is computed by HMI from admitted evidence, not copied from a study baseline. It describes the evidence currently in this scope; it is not a worldwide or current-lot benchmark. Source, year and region filters do not change it. Different HMI scopes are not one common ranking.