Rice finding 538

Source evidence and comparison details for the Rice profile.

Cooking et al. 2021

Raw (crude) rice grain, dried; milling degree not stated · Cadmium (Cd) · 10 10 samples of 10 kg per rice type (6 types); each chemical experiment in ten replications.

Selected finding and reference

30.7 µg/kg (mean)Mean.

10 10 samples of 10 kg per rice type (6 types); each chemical experiment in ten replications. Basis: dry weight.

no non-detects reported

HMI baseline position

Moderate · HMI dry-grain Cd reference · 9 sampling families. Mean as reported: 30.7 µg/kg. HMI median 71; Q1 4.7–9 (bounded); Q3 149 µg/kg. 9 families. Not a safety grade.

Low is below Q1; Moderate includes Q1 through Q3; High is above Q3. Reporting bounds must give the same category throughout.

This is an external comparison; the finding does not set the reference.

Sensitivity to weighting

Equal subgroup weight within each family: Moderate. The position is unchanged under this alternative. This check does not address all sampling, rounding or analytical uncertainty.

Sensitivity to source selection

These checks show dependence on each sampling family; they are not confidence intervals.

Reference, contributing evidence and methods

Collection period

Collection date unreported

No year-by-year sample register is reconstructed from this summary.

Geographic scope

Imported I

Reported growing area.

Sampling, analysis and reporting limits

Microwave acid digestion (500 mg dry sample, 9 mL HNO3 : 3 mL HCl; Ethos Up SK-12), ICP-MS (Agilent 7700X) for total Pb and Cd.

no non-detects reported

Source inconsistency noted (does not affect this value): the Conclusion states Pb and Cd exceeded the WHO limits (150 and 60 ppb) in all crude rice samples, but this mean is below that limit.

Shared samples and study overlap

Subgroup rows, statistics of the same subgroup and the study total share samples; they are not independent results.

Each table row describes a food/analyte result. Repeated rows do not add independent samples or datasets. No cross-study trend is calculated in this comparison mode.

Reported values, conversion and source locator
Source statisticOriginal resultDisplayed unit conversion
mean30.74 ± 5.67none

Table 2, Crude rice (Blank) column, row Imported I, p.5115.

No moisture, cooking-yield or species conversion is applied to the original finding above. Any basis conversion used for its HMI comparison is stated separately with the numerical target.

Open the primary publication · HMI source record

Reference and scope

HMI dry-grain Cd reference · 9 sampling families. Dry-weight grain, µg/kg dry weight. Distribution of subgroup median concentration values.

Reference (µg/kg)Q1MedianQ3
Primary HMI reference4.7–9 (bounded)71149
Alternative weighting4.7–9 (bounded)71149

65 reference units; 9 sampling families. Counts describe evidence units, not independent studies or certainty.

Contributing familyReference unitsWeight
Myat Soe et al. (2023)511%
Shi et al. (2020)3211%
WHO GEMS/Food111%
Huang 2023311%
Li et al. 2022511%
Qin et al. 2026511%
Signes-Pastor et al. 2016911%
TatahMentan et al. 2020311%
Xie et al. 2026211%

Methods

HMI calculates a pooled distribution of subgroup medians across the admitted sampling families. HMI pools subgroup medians from every compatible rice sampling family in the evidence ledger for this analyte, material and basis: published subgroup medians, medians HMI calculates from printed per-sample values and WHO GEMS/Food region-by-year medians (random sampling only). Each family has equal total weight; subgroups have equal weight within a family. Non-detects stay as zero-to-limit intervals, so quartiles carry lower and upper bounds. Means, ranges and maxima never enter as observations. Dry-weight, native-moisture and cooked results are kept in separate references; no moisture conversion is assumed.

Inverse weighted empirical CDF; midpoint at exact cumulative-weight boundaries. At least four reference units and a definitely positive Q1–Q3 spread are required. This is a display eligibility rule, not statistical validation.

Limitations

An evidence-library reference, not a probability sample of the world rice market. Sampling families differ in frame (retail, farm, contaminated sites, monitoring) and period; GEMS/Food regions are reporting regions, not growing origins. Many submissions are non-detects with differing limits, which widens the bounds. A position is descriptive concentration, not a safety or compliance judgment.

Admitted source families

Reference version and interpretation

Frozen evidence selection: 2026-10-22. Method: hmi-pooled-reference-v2.

hmi-pooled-reference-v2:rice-dry-Cd:59d3645f9f4f

The reference is computed by HMI from admitted evidence, not copied from a study baseline. It describes the evidence currently in this scope; it is not a worldwide or current-lot benchmark. Source, year and region filters do not change it. Different HMI scopes are not one common ranking.