Rice finding 2594

Source evidence and comparison details for the Rice profile.

Signes-Pastor et al. 2016

Polished white rice (commercial) · Dimethylarsinic acid (DMA) · 14 rice samples (field composites per site; commercial packs).

Selected finding and reference

34–237 µg/kg (range)Range.

14 rice samples (field composites per site; commercial packs). Basis: dry weight.

Values below LOD assigned 1/2 LOD by the source for statistics (Section 2.5); medians/min reported as printed

HMI baseline position

Limited data: The source reports a range, percentile or extreme value; only a mean, median or sample result can be positioned against a reference. Missing evidence never means low contamination.

The source reports a range, percentile or extreme value; only a mean, median or sample result can be positioned against a reference.

Reference version and interpretation

Frozen evidence selection: 2026-10-22. Method: hmi-pooled-reference-v2.

No admitted reference

The reference is computed by HMI from admitted evidence, not copied from a study baseline. It describes the evidence currently in this scope; it is not a worldwide or current-lot benchmark. Source, year and region filters do not change it. Different HMI scopes are not one common ranking.

Collection period

2014

No year-by-year sample register is reconstructed from this summary.

Geographic scope

Catalunya

Reported growing area.

Sampling, analysis and reporting limits

Freeze-dried, ball-milled; 1% HNO3 microwave extraction with H2O2 oxidation, IC-ICP-MS (Thermo AS7 column, iCAP Q) for As species; HNO3/H2O2 microwave digestion and ICP-MS for Cd.

Values below LOD assigned 1/2 LOD by the source for statistics (Section 2.5); medians/min reported as printed

Shared samples and study overlap

Subgroup rows, statistics of the same subgroup and the study total share samples; they are not independent results.

Each table row describes a food/analyte result. Repeated rows do not add independent samples or datasets. No cross-study trend is calculated in this comparison mode.

Reported values, conversion and source locator
Source statisticOriginal resultDisplayed unit conversion
range0.057ac (0.034–0.237)mg/kg x 1000

Table 1, p.360, Polished, Catalunya row.

No moisture, cooking-yield or species conversion is applied to the original finding above. Any basis conversion used for its HMI comparison is stated separately with the numerical target.

Open the primary publication · HMI source record