Rice finding 1471

Source evidence and comparison details for the Rice profile.

Tran et al. 2024

White rice · Lead (Pb) · 184 genotypes (3 replicate 1 m2 plots each; 10 grains per plot ground).

Selected finding and reference

Not detected (no numerical limit reported)Below detection limit.

184 genotypes (3 replicate 1 m2 plots each; 10 grains per plot ground). Basis: air-dried grain (ground).

all results below the (unstated) quantification limit; excluded from analysis by the authors; no values reported

HMI baseline position

Limited data: The source reports a non-detect without a numerical limit; its position cannot be identified. Missing evidence never means low contamination.

The source reports a non-detect without a numerical limit; its position cannot be identified.

Reference version and interpretation

Frozen evidence selection: 2026-10-22. Method: hmi-pooled-reference-v2.

No admitted reference

The reference is computed by HMI from admitted evidence, not copied from a study baseline. It describes the evidence currently in this scope; it is not a worldwide or current-lot benchmark. Source, year and region filters do not change it. Different HMI scopes are not one common ranking.

Collection period

2019

No year-by-year sample register is reconstructed from this summary.

Geographic scope

Vietnamese rice collection

Rice variety or type within one study.

Sampling, analysis and reporting limits

HNO3 (In internal standard) + H2O2 block digestion at 115 C; ICP-MS PerkinElmer NexION 2000, He collision mode, University of Nottingham ionomics platform; external calibration.

all results below the (unstated) quantification limit; excluded from analysis by the authors; no values reported

Shared samples and study overlap

Subgroup rows, statistics of the same subgroup and the study total share samples; they are not independent results.

Each table row describes a food/analyte result. Repeated rows do not add independent samples or datasets. No cross-study trend is calculated in this comparison mode.

Reported values, conversion and source locator
Source statisticOriginal resultDisplayed unit conversion
below_LODLi, B, Na, Ti, Cr, Se and Pb concentrations were below the quantification limits. These latter elements were consequently excluded from further analysis.none

Results, first paragraph (line 87, before Table 1).

No moisture, cooking-yield or species conversion is applied to the original finding above. Any basis conversion used for its HMI comparison is stated separately with the numerical target.

Open the primary publication · HMI source record