Rice finding 1229

Source evidence and comparison details for the Rice profile.

Hao et al. 2022

Brown rice (husked; field-collected paddy threshed to brown rice) · Total chromium (Cr) · 220 site composites (5 sub-samples per site).

Selected finding and reference

1–12,400 µg/kg (range)Range.

220 site composites (5 sub-samples per site). Basis: air-dried to <13% moisture (as-analysed brown rice powder).

Treatment of values below the method detection limit not stated

HMI baseline position

Limited data: The source reports a range, percentile or extreme value; only a mean, median or sample result can be positioned against a reference. Missing evidence never means low contamination.

The source reports a range, percentile or extreme value; only a mean, median or sample result can be positioned against a reference.

Reference version and interpretation

Frozen evidence selection: 2026-10-22. Method: hmi-pooled-reference-v2.

No admitted reference

The reference is computed by HMI from admitted evidence, not copied from a study baseline. It describes the evidence currently in this scope; it is not a worldwide or current-lot benchmark. Source, year and region filters do not change it. Different HMI scopes are not one common ranking.

Collection period

Collection date unreported

No year-by-year sample register is reconstructed from this summary.

Geographic scope

Xiangtan County

Sampling site within one study.

Sampling, analysis and reporting limits

Pb, Cd, Cr: HNO3-HClO4 (9:1) digestion, ICP-MS (Thermo XSeries 2); tAs: HNO3-HClO4 wet digestion, AFS; Hg: microwave digestion, AFS; iAs: 0.15 mol/L HNO3 extraction 90 °C 2.5 h, LC-AFS (GB 5009.11-2014 approach).

Treatment of values below the method detection limit not stated

Source inconsistency noted (does not affect this value): printed minimum 0.001 mg/kg is below the stated method detection limit (0.05 mg/kg); handling of sub-MDL values is not described.

Shared samples and study overlap

Subgroup rows, statistics of the same subgroup and the study total share samples; they are not independent results.

Each table row describes a food/analyte result. Repeated rows do not add independent samples or datasets. No cross-study trend is calculated in this comparison mode.

Reported values, conversion and source locator
Source statisticOriginal resultDisplayed unit conversion
range[0.001,12.38]mg/kg x 1000

Table 2 (Concentration characteristics of iAs and some heavy metals in rice, N=220), p.11514; Results 'Contamination profile' text.

No moisture, cooking-yield or species conversion is applied to the original finding above. Any basis conversion used for its HMI comparison is stated separately with the numerical target.

Open the primary publication · HMI source record